What is a capacitor start or capacitor run in a motor ?

A capacitor start or capacitor run motor is a type of single-phase induction motor that utilizes capacitors to improve its starting torque and operational efficiency. These motors are commonly used in applications where starting torque is crucial, such as in compressors, pumps, and air conditioning units. There are two main types within this category: capacitor start and capacitor run motors.

Capacitor start motors use a capacitor during the starting phase to create a rotating magnetic field necessary for starting. A large electrolytic capacitor is connected in series with the starting winding of the motor. This capacitor provides a phase shift between the currents in the starting and running windings, creating the initial torque needed to start the motor from standstill. Once the motor reaches approximately 75-80% of its rated speed, a centrifugal switch disconnects the starting capacitor from the circuit to prevent it from affecting the motor’s efficiency during normal operation.

Capacitor run motors, on the other hand, use a capacitor that remains connected to the motor during both starting and running operation. This capacitor improves the power factor and efficiency of the motor while running, ensuring smooth operation and reducing energy consumption. Capacitor run motors typically have a higher efficiency and longer lifespan compared to capacitor start motors due to the continuous use of the capacitor to improve motor performance.

A run capacitor in a motor is connected in series with the motor’s auxiliary winding (often called the run winding). Its primary function is to improve the power factor and efficiency of the motor during operation by creating a phase shift between the current in the main winding and the auxiliary winding. This phase shift helps to optimize the motor’s performance, reduce power consumption, and enhance the torque characteristics. Unlike start capacitors, run capacitors are designed to remain connected to the motor circuit throughout its operation, continuously improving efficiency.

To determine if a motor has a start or run capacitor, you can typically check the motor’s nameplate or specifications provided by the manufacturer. The nameplate will usually indicate whether the motor uses a capacitor start mechanism, a capacitor run mechanism, or a combination of both. Additionally, visually inspecting the motor itself may reveal the presence of capacitors connected to either the starting winding (for capacitor start motors) or the auxiliary winding (for capacitor run motors). Capacitor terminals may also be visible on the motor housing, indicating their presence and function.

In a capacitor start motor, the capacitor is indeed connected to the motor’s starting winding. This capacitor is crucial during the starting phase as it provides the necessary phase shift to create starting torque. Once the motor reaches a certain speed (typically around 75-80% of its rated speed), a centrifugal switch disconnects the starting capacitor from the circuit to prevent it from affecting the motor’s efficiency during normal operation. This design ensures that the motor can start effectively with enhanced torque characteristics while operating efficiently once it reaches its operating speed.